Electrical & Electronics

Linear Regulator & LDO Calculator

Estimate linear-regulator power loss, efficiency, dropout margin, junction temperature and load limits.

01

Your inputs

Steady-state estimate; θJA depends on PCB and airflow. Use datasheet values at the required load and temperature.

Power and heat assume the target output is regulated. A negative dropout margin means it cannot be maintained.

TI SNVA419C

02

Your results

Regulator dissipation
—
Estimated efficiency
—
Dropout margin
—
Junction temperature estimate
—
Temperature margin
—
Maximum load within entered limits
—

Formula—

Transistor Thermal & Heatsink Calculator

Check regulator dropout and heat separately

Estimate linear-regulator loss, efficiency and junction temperature for an entered load. Compare dropout, current and thermal limits independently. These are steady-state estimates from supplied assumptions, not a device-specific regulation or transient model.

Step by step

  1. Enter input and desired output voltages, load current and quiescent current with their displayed units.
  2. Enter dropout, current limit, ambient temperature, junction limit and thermal resistance from relevant device conditions.
  3. Inspect every limit warning and the maximum-load estimate, not only voltage headroom.

Settings and limits

Dropout assumption
Dropout margin compares available voltage with the entered requirement. Real dropout depends on current and temperature.
Quiescent current
The model counts quiescent current drawn from the input in power loss and efficiency. Check the device's definition.
Thermal resistance
Use a θJA appropriate to the package, board and cooling. A typical datasheet value may not describe your layout.

Worked example

The lower-load example passes the entered limits. Its junction temperature includes both load loss and quiescent power.

Example input

Vin = 12 V; Vout = 5 V; Iq = 50 µA
Vdropout = 0.3 V; Ilimit = 500 mA
TA = 25 °C; TJmax = 125 °C; θJA = 50 °C/W
Expected result
IloadPdTJTJmax − TJImax
100 mA0.7006 W60.03 °C64.97 °C285.628571 mA
400 mA2.8006 W165.03 °C−40.03 °C285.628571 mA

Increasing load as shown causes overheating even though dropout and the entered current limit still pass.

Questions and troubleshooting

Why is maximum load below the current limit?

Thermal headroom can impose a tighter limit. The estimate also becomes zero when the dropout requirement is unmet.

Does a dropout warning predict output voltage?

No. It flags failure to meet the requested operating condition; it does not model the resulting output.

Does passing every check prove suitability?

No. Check capacitor stability, startup, transients, protection behaviour and derating in the selected device's datasheet.